WU Hong-wen, WU Min. Determination of sulfadiazine in compound nasal ointment by RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (6): 333-335.
Citation: WU Hong-wen, WU Min. Determination of sulfadiazine in compound nasal ointment by RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (6): 333-335.

Determination of sulfadiazine in compound nasal ointment by RP-HPLC

  • Received Date: 2003-12-22
  • Objective To establish a method for determination of the content of sulfadiazine in compound nasal ointment.Methods RP-HPLC was adopted with Shim-pack VP-ODS(250L×4.6) column as analytical column, methanol-water-aceti-cacid (40:60:0.1) as mobile phase.The detection wavelength was 270nm.The flow rate was 0.6mL/min. Results The linear ranges of sulfadiazine were 11.26-123.82μg/mL,Y = 144647X-41558,r =0.9999,the average recovery was (100.2±1.5)%,RSD was 1.4%(n=6).Conclusion The method is simple, rapid, accurate and suitable for the determination of sulfadiazine in compound nasal ointment.
  • 加载中
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2787) PDF downloads(388) Cited by()

Related
Proportional views

Determination of sulfadiazine in compound nasal ointment by RP-HPLC

Abstract: Objective To establish a method for determination of the content of sulfadiazine in compound nasal ointment.Methods RP-HPLC was adopted with Shim-pack VP-ODS(250L×4.6) column as analytical column, methanol-water-aceti-cacid (40:60:0.1) as mobile phase.The detection wavelength was 270nm.The flow rate was 0.6mL/min. Results The linear ranges of sulfadiazine were 11.26-123.82μg/mL,Y = 144647X-41558,r =0.9999,the average recovery was (100.2±1.5)%,RSD was 1.4%(n=6).Conclusion The method is simple, rapid, accurate and suitable for the determination of sulfadiazine in compound nasal ointment.

WU Hong-wen, WU Min. Determination of sulfadiazine in compound nasal ointment by RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (6): 333-335.
Citation: WU Hong-wen, WU Min. Determination of sulfadiazine in compound nasal ointment by RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (6): 333-335.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return