YU Dexun, HUANG Xinhui, ZHU Kehan, HUANG Ting, ZHOU Tingting, GAO Jianyi. Acetaminophen content assay with UHPLC in the sustained-release tablet exposed to radiation[J]. Journal of Pharmaceutical Practice and Service, 2022, 40(6): 550-552, 562. doi: 10.12206/j.issn.2097-2024.202109100
Citation: YU Dexun, HUANG Xinhui, ZHU Kehan, HUANG Ting, ZHOU Tingting, GAO Jianyi. Acetaminophen content assay with UHPLC in the sustained-release tablet exposed to radiation[J]. Journal of Pharmaceutical Practice and Service, 2022, 40(6): 550-552, 562. doi: 10.12206/j.issn.2097-2024.202109100

Acetaminophen content assay with UHPLC in the sustained-release tablet exposed to radiation

doi: 10.12206/j.issn.2097-2024.202109100
  • Received Date: 2021-09-18
  • Accepted Date: 2021-12-16
  • Rev Recd Date: 2021-11-24
  • Available Online: 2022-11-28
  • Publish Date: 2022-11-25
  •   Objective  To assay the contents of acetaminophen with ultra high-performance liquid chromatography (UHPLC) method in the sustained-release tablets radiated by Gamma ray.   Methods   Acetaminophen sustained-release tablets were radiated by 60Co. UHPLC equipped with the Shim-pack GISS-C18(2.1 mm×50 mm, 1.9 μm)was used for the assay. The mobile phase was methanol-0.05 % ammonium acetate solution (15∶85). The flow rate was 0.3 ml/min with the detection wavelength at 245 nm.   Results  The acetaminophen showed good linear relationship within the range of 20-100 μg/ml (r=0.999 4). The RSD values of repeatability was 0.9 %. The average recovery was 97.9 %-104.9 %. Acetaminophen content was 96.2 %, 92.2 %, 91.8 %, 83.9 % at 0, 8, 50 and 80 kGy radiation, respectively.   Conclusion  This method is speedy and accurate. It can be used to assay the content of acetaminophen in the sustained-release tablets after radiation. The content of acetaminophen decreased after radiation.
  • [1] CHANCELLOR J C, SCOTT G B I, SUTTON J P. Space radiation: the number one risk to astronaut health beyond low earth orbit[J]. Life Basel Switz,2014,4(3):491-510.
    [2] 赵元. 对乙酰氨基酚: 能最小限度地缓解膝关节炎的疼痛[J]. 心血管病防治知识(科普版), 2017(9):52.
    [3] 肖壮, 唐涛, 孙先润, 等. 骨关节炎治疗药物的研究进展[J]. 中国药房, 2016, 27(35):5037-5040. doi:  10.6039/j.issn.1001-0408.2016.35.47
    [4] 尤启冬. 药物化学[M]. 8版. 北京: 人民卫生出版社, 2016: 257-258.
    [5] 王二兵, 赵正保, 曲婷丽. 60Co辐照灭菌对止嗽立效口服液主要成分的影响[J]. 中成药, 2013, 35(9):2056-2058. doi:  10.3969/j.issn.1001-1528.2013.09.058
    [6] 国家药典委员会. 中华人民共和国药典(四部)2020版[S]. 北京: 中国医药科技出版社, 2020: 387.
    [7] 谢笑英, 黄文峰. 中成药中对乙酰氨基酚含量测定的4种方法及比较[J]. 河北医学, 2005, 11(6):563-565. doi:  10.3969/j.issn.1006-6233.2005.06.043
    [8] 孙晶, 薛壮. 常用解热镇痛药中对乙酰氨基酚含量测定[J]. 科技视界, 2014(5):184-185.
    [9] 中华人民共和国卫生部. 60Co辐照中药灭菌剂量标准(卫药发[1997]第38号文件)[S]. 1997.
    [10] United States Pharmacopeial Convention. United States Pharmacopoeia [S]. 42 edition. NF37. Rockville : The United States Pharmacopeial Convention Press, 2019: 292.
  • 加载中
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Figures(1)  / Tables(3)

Article Metrics

Article views(6865) PDF downloads(19) Cited by()

Related
Proportional views

Acetaminophen content assay with UHPLC in the sustained-release tablet exposed to radiation

doi: 10.12206/j.issn.2097-2024.202109100

Abstract:   Objective  To assay the contents of acetaminophen with ultra high-performance liquid chromatography (UHPLC) method in the sustained-release tablets radiated by Gamma ray.   Methods   Acetaminophen sustained-release tablets were radiated by 60Co. UHPLC equipped with the Shim-pack GISS-C18(2.1 mm×50 mm, 1.9 μm)was used for the assay. The mobile phase was methanol-0.05 % ammonium acetate solution (15∶85). The flow rate was 0.3 ml/min with the detection wavelength at 245 nm.   Results  The acetaminophen showed good linear relationship within the range of 20-100 μg/ml (r=0.999 4). The RSD values of repeatability was 0.9 %. The average recovery was 97.9 %-104.9 %. Acetaminophen content was 96.2 %, 92.2 %, 91.8 %, 83.9 % at 0, 8, 50 and 80 kGy radiation, respectively.   Conclusion  This method is speedy and accurate. It can be used to assay the content of acetaminophen in the sustained-release tablets after radiation. The content of acetaminophen decreased after radiation.

YU Dexun, HUANG Xinhui, ZHU Kehan, HUANG Ting, ZHOU Tingting, GAO Jianyi. Acetaminophen content assay with UHPLC in the sustained-release tablet exposed to radiation[J]. Journal of Pharmaceutical Practice and Service, 2022, 40(6): 550-552, 562. doi: 10.12206/j.issn.2097-2024.202109100
Citation: YU Dexun, HUANG Xinhui, ZHU Kehan, HUANG Ting, ZHOU Tingting, GAO Jianyi. Acetaminophen content assay with UHPLC in the sustained-release tablet exposed to radiation[J]. Journal of Pharmaceutical Practice and Service, 2022, 40(6): 550-552, 562. doi: 10.12206/j.issn.2097-2024.202109100
  • 长期的航天载人飞行的特殊环境会影响航天员的生活质量和身体健康,因此,需要安全、有效的药物进行预防、治疗,以保障航天员的身体健康。然而,空间环境与地面环境有较大的不同,在地面上空气、温度、湿度、日光灯是主要影响药物稳定性的因素,需要规定药物的储存条件以保证药物在一定有效期内可以安全使用。但是,航天环境中的稳定性因素主要是空间辐射,包括非电离辐射和电离辐射。在执行航天任务的过程中,宇航员会受到空间电离辐射的影响。美国航空航天局(NASA)认为,空间辐射在未来可能会成为人类进行深空探测活动的最大限制因素之一[1]。其中的非电离辐射可以被药品的包装等屏蔽,而电离辐射的γ射线、χ射线等电磁波以及电子、质子、高能粒子等则难以完全屏蔽,会使药物的结构发生一定变化,从而导致其失效。

    对乙酰氨基酚具有解热镇痛作用,临床上主要用于缓解轻、中度疼痛,如能最小限度地缓解膝关节的疼痛,是轻型骨关节炎短期镇痛的首选药物,广泛用于发热、头痛、神经痛以及痛经等症状,是常用的非处方药,也是航天飞行中的必备药物[2-4]

    为了考察对乙酰氨基酚缓释片在太空环境中的稳定性,本研究采60Co辐射模拟太空的射线环境。60Co是金属元素钴的放射性同位素之一,是一种穿透力很强的核辐射元素,通过β衰变释放能量产生β射线和γ射线。而太空辐射是一种包含γ射线、高能质子和宇宙射线的特殊混合体,60Co辐射和太空辐射都包含γ射线,且60Co的γ射线有很强的穿透力,效果显著,具有常温常压可处理,方法简单,成本低廉等优点[5],常以放射源形式在各行各业广泛应用,因此,可以选择60Co辐射模拟太空的射线环境。

    本文建立UHPLC法测定不同辐射剂量下的对乙酰氨基酚缓释片的含量变化,为太空环境下药品稳定性研究提供以辐射因素为主的研究思路,以揭示辐射因素对常用航天化学药品质量稳定性的影响,从而,可科学预测太空环境中药品的有效期,为今后航天药品的制剂工艺、包装储存等提供依据。

    • LC-2030 PLUS高效液相色谱仪(日本岛津公司);电子天平(北京赛多利斯科学仪器有限公司);60Co辐照装置(海军军医大学海军医学系辐照中心)。

      对乙酰氨基酚缓释片(上海强生制药有限公司,批号:190611);对乙酰氨基酚对照品(中国食品药品检定研究院,批号:100802-20100, 含量99.8%);甲醇(Merck)、乙酸铵(Fisher)均为色谱纯;水为自制纯化水。

    • 将对乙酰氨基酚缓释片(含包装)置于辐照环境中,设定剂量辐射率,按照接收剂量为0、8、50、80 kGy进行60Co辐射,每天辐射1次,于1个月后取样。

    • 取对乙酰氨基酚对照品约20 mg,精密称定,置10 ml量瓶中,加溶剂甲醇-水(4∶6)溶解并稀释至刻度,摇匀,得对乙酰氨基酚对照品储备液;再精密量取2 ml置100 ml量瓶中,加溶剂稀释至刻度,摇匀,得浓度为40 μg/ml的对照品溶液。

    • 取经0、8、50、80 kGy辐射后对乙酰氨基酚缓释片各10片,精密称定,研细,精密称取细粉适量(约相当于对乙酰氨基酚20 mg)置10 ml量瓶中,加溶剂甲醇-水(4∶6)溶解并稀释至刻度,摇匀,再精密量取续滤液2 ml,置100 ml量瓶中,加溶剂稀释至刻度,摇匀,用0.45 μm微孔滤膜过滤,得供试品溶液。

    • 色谱柱为Shim-pack GISS C18色谱柱(2.1 mm×50 mm,1.9 μm)。流动相为甲醇-0.05%乙酸铵溶液(15∶85),检测波长为245 nm,流速为0.3 ml/min,柱温40 ℃,进样量为10 μl,色谱图中对乙酰氨基酚的保留时间为2.67 min,理论塔板数按对乙酰氨基酚峰计算大于5000。精密称取标准品配制浓度约为40 μg/ml的对照品溶液,在上述色谱条件下重复进样6次,测定峰面积,计算峰面积RSD为0.02%,表明仪器精密度良好。每个辐射强度取1批供试品,按照“2.3”项下配制供试品溶液,此色谱条件下进样分析。对照品溶液及供试品溶液的色谱结果见图1

    • 精密量取对乙酰氨基酚对照品储备液1、2、3、4、5 ml,置100 ml量瓶中,加溶剂稀释至刻度,摇匀,得浓度分别为20、40、60、80、100 μg/ml的工作曲线。按“2.4”项下色谱条件分别进样10 μl进行测定,记录色谱图。以对乙酰氨基酚对照品浓度 (μg/ml)为横坐标,相应峰面积为纵坐标,绘制标准曲线,得回归方程为Y= 2.72×105X+1.5×104r=0.9997,结果表明,对乙酰氨基酚在20~100 μg/ml浓度范围内,线性关系良好。

    • 精密称取同一批未辐射的对乙酰氨基酚缓释片样品6份,按照“2.3”项下方法制成供试品溶液,按“2.4”项下色谱条件分别进样10 μl测定,记录峰面积,计算含量,其RSD为0.9%(表1),表明该方法重复性良好。

      编号含量(%)平均含量(%)RSD(%)
      196.996.90.9
      297.9
      398.3
      495.8
      596.1
      696.3
    • 精密称取同一批未辐射的对乙酰氨基酚缓释片样品(约相当于对乙酰氨基酚20 mg)各3份,样品分别置于10 ml容量瓶中,再精密称取对乙酰氨基酚对照品16、20、24 mg各3份,置于上述3个量瓶中,加溶剂(甲醇-水为4∶6)溶解并稀释至刻度,摇匀,再精密量取续滤液2 ml,置于100 ml量瓶中,加溶剂稀释至刻度,摇匀,每个浓度制备3份,照“2.4”项下色谱条件进样分析,计算回收率结果见表2

      称量量
      (m/mg)
      原有量
      (m/mg)
      测得量
      (m/mg)
      加入量
      (m/mg)
      回收率
      (%)
      平均回收率
      (%)
      RSD
      (%)
      25.6120.9837.1915.98101.4101.51.6
      25.6220.9937.21101.5
      25.6220.9937.13101.0
      25.6321.0042.1920.84101.7
      25.6321.0042.11101.3
      25.6220.9942.85104.9
      25.6321.0045.4924.01102.0
      25.6321.0044.5197.9
      25.6321.0045.49102.0
    • 取辐射强度为8 kGy的供试品,按“2.3”项下方法制备供试品溶液,按含量测定方法测定,在0、1、2、5、8、12 h分别进样10 μ1,记录峰面积,结果RSD为0.19%,表明溶液在12 h内稳定。

    • 每个辐射强度取1批供试品,按“2.3”项下方法制备供试品溶液,平行3份,按“2.4”项下色谱条件进样分析,记录色谱峰面积,按照外标法计算对乙酰氨基酚含量。结果见表3

      辐射剂量(kGy)含量(%)平均含量(%)
      096.396.2
      95.2
      97.3
      894.292.2
      90.3
      92.1
      5090.891.8
      93.0
      91.7
      8081.783.9
      83.0
      86.8
    • 对乙酰氨基酚片剂含量测定的常用方法,主要有紫外分光光度法、双波长分光光度法、高效液相色谱法等[6-8]。而常规高效液相色谱法,主峰出峰时间较长,若要缩短出峰时间,则会受到干扰。超高效液相色谱法粒径更小,柱效更高,可使主峰峰形较好且出峰较快,可在5 min内测定对乙酰氨基酚缓释片主成分含量,便于大量辐射样品的测定,快速且准确。

    • 根据原中华人民共和国卫生部发布的《60Co辐射中药灭菌剂量标准》[9]和《美国药典》第42版[10] 对辐射灭菌的规定,选定用8、50、80 kGy来考察不同辐射剂量下对乙酰氨基酚缓释片的质量稳定性。结果显示,随着辐射剂量逐步增大,在其他条件相同的情况下,对乙酰氨基酚缓释片的主药含量逐步下降,降解程度超过10%。提示辐射强度越高,药物降解的程度越大。